GI Channels & Profiles
Steel Framing, Studs & Sections
Priced on enquiry
Section, thickness and length are set by the job's engineering, so this is quoted against your bill of materials.
Tell us the size and where it is going.
About this product
- What it is: Cold roll-formed galvanized steel sections, bent from coil to a fixed cross-section (C…
- Who buys it: Hoarding and cladding contractors framing behind sandwich panel or GI sheet…
- Made of: Galvanized steel coil, roll-formed to section then cut to length - the zinc coating…
- Common sections: C-channel and U-channel for framing and track, Z-purlin for roof/wall girts spanning…
- Installation: Bolted or screw-fixed to the primary steel structure at the spacing the panel or cladding…
- Delivery: All 7 Emirates from our own yard.
All 22 sizes
Every size on one list. Tap any row to ask about that one.
| Size / product | Details | Enquire |
|---|---|---|
| C-Channel — 48 mm × 3 mLY-BLDG-042 | 0.35–0.90 mm base metal · the width is the stud size, so it must match the track. | Ask |
| C-Channel — 50 mm × 3 mLY-BLDG-106 | 0.35–0.90 mm base metal · the common partition stud. | Ask |
| C-Channel — 64 mm × 3 mLY-BLDG-107 | 0.35–0.90 mm base metal. 64 mm x 3 m. | Ask |
| C-Channel — 70 mm × 3 mLY-BLDG-108 | 0.35–0.90 mm base metal. 70 mm x 3 m. | Ask |
| C-Channel — 92 mm × 3 mLY-BLDG-109 | 0.35–0.90 mm base metal · deeper stud for a taller partition. | Ask |
| C-Channel — 100 mm × 3 mLY-BLDG-110 | 0.35–0.90 mm base metal. 100 mm x 3 m. | Ask |
| C-Channel — 123 mm × 3 mLY-BLDG-111 | 0.35–0.90 mm base metal. 123 mm x 3 m. | Ask |
| C-Channel — 150 mm × 3 mLY-BLDG-112 | 0.35–0.90 mm base metal · the deepest stud in the range. | Ask |
| U-Channel (track) — 50 mm × 3 mLY-BLDG-043 | Ordered as the matching pair to the 50 mm stud. | Ask |
| U-Channel (track) — 70 mm × 3 mLY-BLDG-113 | Ordered as the matching pair to the 70 mm stud. | Ask |
| U-Channel (track) — 92 mm × 3 mLY-BLDG-114 | Ordered as the matching pair to the 92 mm stud. | Ask |
| U-Channel (track) — 100 mm × 3 mLY-BLDG-115 | Ordered as the matching pair to the 100 mm stud. | Ask |
| U-Channel (track) — 150 mm × 3 mLY-BLDG-116 | Ordered as the matching pair to the 150 mm stud. | Ask |
| Z-Purlin — 142 mm deepLY-BLDG-044 | 1.5–3.0 mm thick · cut to length up to 12 m. Roof and wall girts spanning between main steel. | Ask |
| Z-Purlin — 172 mm deepLY-BLDG-117 | 1.5–3.0 mm thick · cut to length up to 12 m. 172 mm. | Ask |
| Z-Purlin — 202 mm deepLY-BLDG-118 | 1.5–3.0 mm thick · cut to length up to 12 m. 202 mm. | Ask |
| Z-Purlin — 232 mm deepLY-BLDG-119 | 1.5–3.0 mm thick · cut to length up to 12 m. 232 mm. | Ask |
| Z-Purlin — 262 mm deepLY-BLDG-120 | 1.5–3.0 mm thick · cut to length up to 12 m · longer spans. | Ask |
| Z-Purlin — 302 mm deepLY-BLDG-121 | 1.5–3.0 mm thick · cut to length up to 12 m · the deepest section in the range. | Ask |
| Angle Section — to your leg sizesLY-BLDG-045 | Equal and unequal leg, roll-formed from galvanized coil · send leg dimensions, thickness and length. | Ask |
| C-Channel — 89 mm × 3 m | 0.50–0.90 mm base metal · 3½ inch stud, the imperial-derived size · 89 × 41 mm is the common pairing | Ask |
| U-Channel (track) — 89 mm × 3 m | Ordered as the matching pair to the 89 mm stud | Ask |
- 0.35–0.90 mm base metal · the width is the stud size, so it must match the track.Ask on WhatsApp
- 0.35–0.90 mm base metal · the common partition stud.Ask on WhatsApp
- 0.35–0.90 mm base metal. 64 mm x 3 m.Ask on WhatsApp
- 0.35–0.90 mm base metal. 70 mm x 3 m.Ask on WhatsApp
- 0.35–0.90 mm base metal · deeper stud for a taller partition.Ask on WhatsApp
- 0.35–0.90 mm base metal. 100 mm x 3 m.Ask on WhatsApp
- 0.35–0.90 mm base metal. 123 mm x 3 m.Ask on WhatsApp
- 0.35–0.90 mm base metal · the deepest stud in the range.Ask on WhatsApp
- Ordered as the matching pair to the 50 mm stud.Ask on WhatsApp
- Ordered as the matching pair to the 70 mm stud.Ask on WhatsApp
- Ordered as the matching pair to the 92 mm stud.Ask on WhatsApp
- Ordered as the matching pair to the 100 mm stud.Ask on WhatsApp
- Ordered as the matching pair to the 150 mm stud.Ask on WhatsApp
- 1.5–3.0 mm thick · cut to length up to 12 m. Roof and wall girts spanning between main steel.Ask on WhatsApp
- 1.5–3.0 mm thick · cut to length up to 12 m. 172 mm.Ask on WhatsApp
- 1.5–3.0 mm thick · cut to length up to 12 m. 202 mm.Ask on WhatsApp
- 1.5–3.0 mm thick · cut to length up to 12 m. 232 mm.Ask on WhatsApp
- 1.5–3.0 mm thick · cut to length up to 12 m · longer spans.Ask on WhatsApp
- 1.5–3.0 mm thick · cut to length up to 12 m · the deepest section in the range.Ask on WhatsApp
- Equal and unequal leg, roll-formed from galvanized coil · send leg dimensions, thickness and length.Ask on WhatsApp
- 0.50–0.90 mm base metal · 3½ inch stud, the imperial-derived size · 89 × 41 mm is the common pairingAsk on WhatsApp
- Ordered as the matching pair to the 89 mm studAsk on WhatsApp
Section, thickness and length are set by the job's engineering, so this is quoted against your bill of materials.
What it is
Roll-formed galvanized steel channel and profile sections — the structural frame behind hoarding, cladding and drywall. C-channel studs from 48 to 150 mm and matching U-channel track, both 3 m standard, in 0.35–0.90 mm. Z-purlins 142 to 302 mm deep in 1.5–3.0 mm, cut to length up to 12 m. Order the track to match the stud: the width is the same number on both. Track is stocked in 50, 70, 89, 92, 100 and 150 mm, so ask before specifying a 48, 64 or 123 mm stud.
Specification
Everything published for this product. Anything not listed here is not published — ask and we will confirm it for the unit you are buying.
- What it is
- Cold roll-formed galvanized steel sections, bent from coil to a fixed cross-section (C, U, Z or angle), used as the frame that panels, cladding or drywall board get fixed to.
- Who buys it
- Hoarding and cladding contractors framing behind sandwich panel or GI sheet, drywall/partition contractors, and fabricators building light steel frames.
- Made of
- Galvanized steel coil, roll-formed to section then cut to length - the zinc coating (galvanizing) is what lets it sit outdoors without painting.
- Common sections
- C-channel and U-channel for framing and track, Z-purlin for roof/wall girts spanning between main steel, angle section for bracing and trims.
- Installation
- Bolted or screw-fixed to the primary steel structure at the spacing the panel or cladding manufacturer specifies - purlin spacing is set by the wind load and panel span, not a fixed number.
- Delivery
- All 7 Emirates from our own yard. Sharjah and the northern emirates are usually same day on stocked lines; the rest of the country is one to three working days. The delivery charge depends on the emirate, the load and the offloading, and is confirmed in writing on the quotation rather than guessed at here.
- Ordering
- Cut to length on request. Priced per length or per project quantity against a bill of materials, excluding 5% VAT.
Technical Procurement & Ordering Guides
10 drawings covering every answer we need to price GI Channels & Profiles — every figure comes from the price table above or from the published standard it is made to.
The profilesC, U, Z and angle
1 of 10
Send us the size, wall and length — or send the drawing and we will read it off.
Ready to price your gi channels & profiles?
Send us the size and the site. We quote the same day, and we deliver across all seven Emirates.